FOOTPRINT (LxWxH cm) | CARTS | SHELF QTY (MAXIMUM) | SHELF AREA (SQ M) | INTERNATIONAL PRICING (USD)** | |
---|---|---|---|---|---|
PARKER 2 | 557 x 214 x 254 | 2 | 84 | 25.36 | $429,000 |
PARKER 6 | 762 x 214 x 254 | 6 | 252 | 76 | $619,000 |
PARKER 10 | 867 x 191 x 249 | 10 | 420 | 126.8 | $769,000 |
PARKER 10-R | 933 x 247 x 249 | 10 | 420 | 126.8 | $929,000 |
PARKER 16-R | 742 x 318 x 257 | 16 | 672 | 202.9 | $1,550,000 |
CONDENSER UNIT (PARKER-2) | 468 x 127 x 153 | ||||
CONDENSER UNIT (PARKER-10) | 602 x 127 x 153 | ||||
CONDENSER UNIT (R-MODELS) | 585 x 224 x 153 |
*Footprint dimensions denote an open chamber door
**pricing valid outside of Contiguous United States
Parker Freeze Dry vacuum chambers are made of heavy duty Stainless Steel, built in a variety of sizes to fit your production needs. The glass bead blasted finish provides easy to clean surfaces throughout the chamber.
Allen Bradley PLC and Controls make the unit easy to operate by including a graphic overview of the entire system. Features full automation to ramp or reduce heat to control sublimation to preset parameters. Full control of the vacuum, refrigeration system, and data logging allow for trend analysis and cycle development. Optional cart control allows for varying temperatures among individual carts to optimize processing differentiated products within that cycle.
Carts are aluminum construction for maximum heat exchange efficiency utilizing standard sized baking trays. Available in our standard 42-H configuration, or the 34-H for additional clearance in between the trays.
Leybold dry screw vacuum pumps and boosters achieve deep vacuum throughout the process, eliminating oil back steaming risk. They require less frequent maintenance and repairs.
Aluminum plates in parallel circuits form a direct expansion refrigeration coil. High ratio of cold plate surface to capacity achieves quality freeze drying. During post process residual ice is defrosted by recirculating hot gas.
The Magna Condenser Unit from Heatcraft, is an industrial grade condenser unit custom designed specifically for Parker Freeze Dry. For best results, it should be located outdoors and within 60 ft of your chamber.
Our dedicated team of support staff are available for quick response when needed.
Exclusive content available for operators covering maintenance, cleaning, continuing education, parts and service. Subscribe and save with automated shipping of required maintenance items at recommended intervals.
Description | Specification |
---|---|
Cart Capacity | 2 |
Chamber Dimension (Door Open) | 557L x 214W x 254H cm |
Refrigeration Skid | Heatcraft Magna |
Refrigeration Dimensions | 468L x 127W x 153H cm |
Pan Dimension | 67L x 46W x 3H cm |
Maximum Heated Product Pans | 84 |
Usable Shelf Area | 25.36 Sq m |
Shelf Temp Range | -45 to 82 Celcius |
Maximum Vacuum | ≤ 0.01 mbar |
Median Weight Capacity | 226 kg |
Ice Condenser Capacity | 457 kg |
Chamber Standard Operating (dB) | 85 |
Condensor Operating (dB) | 85 |
Power Requirements | 208V / 480V 3 Phase |
Suction Temp | -51 Celcius |
Typical Max Power Usage | 123 FLA at 480V |
PLC Operating System | Windows 10 |
Description | Specification |
---|---|
Cart Capacity | 6 |
Chamber Dimension (Door Open) | 762L x 214W x 254H cm |
Refrigeration Skid | Heatcraft Magna |
Refrigeration Dimensions | 602L x 127W x 153H cm |
Pan Dimension | 67L x 46W x 3H cm |
Maximum Heated Product Pans | 252 |
Usable Shelf Area | 76 Sq m |
Shelf Temp Range | -45 to 82 Celcius |
Maximum Vacuum | ≤ 0.01 mbar |
Median Weight Capacity | 680 kg |
Ice Condenser Capacity | 1138 kg |
Chamber Standard Operating (dB) | 85 |
Condensor Operating (dB) | 85 |
Power Requirements | 480V 3 Phase |
Suction Temp | -51 Celsius |
Typical Max Power Usage | 128 FLA |
PLC Operating System | Windows 10 |
Description | Specification |
---|---|
Cart Capacity | 10 |
Chamber Dimension (Door open) | 867L x 191W x 249H cm |
Refrigeration Skid | Heatcraft Magna |
Refrigeration Dimensions | 602L x 127W x 153H cm |
Pan Dimension | 67L x 46W x 3H cm |
Maximum Heated Product Pans | 420 |
Useable Shelf Area | 126.8 Sq m |
Shelf Temp Range | -45 to 82 Celcius |
Maximum Vacuum | ≤ 0.01 mbar |
Median Weight Capacity | 1134 kg |
Ice Condenser Capacity | 2244 kg |
Chamber Standard Operation (dB) | 85 |
Condenser Operating (dB) | 85 |
Power Requirements | 480V 3 Phase |
Suction Temp | -51 Celcius |
Typical Max Power Usage | 158.3 FLA |
PLC Operation System | Windows 10 |
Description | Specification |
---|---|
Cart Capacity | 10 |
Chamber Dimension (Door open) | 933L x 247W x 249H cm |
Refrigeration Condenser Skid | Heatcraft Magna |
Refrigeration Condenser Skid Dimensions | 585L x 224W x 153H cm |
Pan Dimension | 67L x 46W x 3H cm |
Maximum Heated Product Pans | 420 |
Maximum Shelf Area | 126.8 Sq m |
Shelf Temp Range | -45 to 82 Celcius |
Maximum Vacuum | ≤ 0.01 mbar |
Median Weight Capacity | 1134 kg |
Ice Condenser Capacity | 4352 kg |
Chamber Standard Operation (dB) | 85 |
Condenser Operating (dB) | 85 |
Power Requirements | 480V 3 Phase |
Suction Temp | -51 Celcius |
Typical Max Power Usage | 215 FLA |
PLC Operation System | Windows 10 |
Description | Specification |
---|---|
Cart Capacity | 16 |
Chamber Dimension (Door open) | 742L x 318W x 257H cm |
Refrigeration Skid | Heatcraft Magna |
Refrigeration Dimensions | 585L x 224W x 153H cm |
Pan Dimension | 67L x 46W x 3H cm |
Maximum Heated Product Pans | 672 |
Useable Shelf Area | 202.9 Sq m |
Shelf Temp Range | -45 to 82 Celcius |
Maximum Vacuum | ≤ 0.01 mbar |
Median Weight Capacity | 1184 kg |
Ice Condenser Capacity | 4352 kg |
Chamber Standard Operation (dB) | 85 |
Condenser Operating (dB) | 85 |
Power Requirements | 480V 3 Phase |
Suction Temp | -51 Celcius |
Typical Max Power Usage | 325 FLA |
PLC Operation System | Windows 10 |